Header image  

Specialist in Acoustic Components

 
  HOME ::
   

 

Measurement method of earphone 耳機測試方法
 

Receiver

Microphone

 

Reliability
1 Load Test 1mW(0.18V) white noise (-filter) is applied for 12 hours satisfy.
2 High Temp. Test Keep 12 hours at +65℃ ±3℃ Humidity 20~25% and leave 1 hour in normal
    ltemperature and then check.
3 Low Temp. Test Keep 12 hours at -12℃ ±3℃ Humidity 20~25% and leave 1 hour in normal temperature and then check.
4 Humidity Test Keep 12 hours at Humidity 90~95%,50℃ ±2℃ and leave 1 hour in normal temperature and then check.
5 Drop Test Normal after dropping to concrete floor for 75 cm height for 2times.
6 Plug pull Test The plug withstands a force 3KG force pull test for one minute.
7 Cord pull Test Normal when a force of 3KG.applied parallel to both ends for one minute.
10 Weight 16g
09 Channel Balance Max. 4dB at 1K Hz
B.MICROPHONE    
10 Directivity Omnidirectional
11 Sensitivity -40±4dB (0dB=1V/Pa,1KHz)
12 Output Impedance (Max) 2.2KΩ
13 Standard Operation Voltage 2.0V
14 Current Consumption Max.0.5mA
15 S/N Ratio > 50dB
16 Parallel Capacitance 1000pf
C.CABLE    
15 Plug RECEIVER : Φ3.5mm 3 Polarity
    MICROPHONE : Φ3.5mm 3 Polarity
16 Net Weight 25g±3
17 Color BLACK